Hi, I have built a microvawe transformer spotwelder, I have put a single turn of welder wire for in the secondary and I’m timing it with arduino. Worth mentioning it was/is a 230V transformer. Electrodes are sharpened copper rods. I believe the voltage is still high. The spotwelds it produces are slightly discolored and not as strong as you would expect. Is this design fundamentally borked? Is there anything else I can make to make it better? Photo from test stage before it was built into a project box, it is less “shocking” now.

  • glibg10b@lemmy.ml
    link
    fedilink
    English
    arrow-up
    4
    ·
    1 year ago

    I believe the voltage is still high

    I believe there are devices that can measure such things

  • DontNoodles@discuss.tchncs.de
    link
    fedilink
    English
    arrow-up
    2
    ·
    1 year ago

    I don’t have any improvements to offer but I want to mention that I saw a crazy video that used a circuit breaker as a spot welding device. The concept is pretty much right and it is as cheap as it can gets, but it is electroboom kind of crazy and the guy even hurt himself on camera while using it.

  • SomeoneSomewhere@lemmy.nz
    link
    fedilink
    English
    arrow-up
    1
    ·
    11 months ago

    Are you able to measure the input current during a weld?

    I suspect you might not have enough copper in the secondary. Fully insulated wires take up a lot of space; there’s a reason magnet wire is commonly used. Several parallel turns of e.g. 6mm^2 magnet wire would be preferable.

    Your SSR generally should be in the phase, not the neutral.

  • Darkassassin07@lemmy.ca
    link
    fedilink
    English
    arrow-up
    1
    ·
    edit-2
    1 year ago

    If it’s a 240v transformer, the primary will have less turns than a 120v one. You may not have a high enough voltage out of your new secondary because of that.

      • Darkassassin07@lemmy.ca
        link
        fedilink
        English
        arrow-up
        2
        ·
        1 year ago

        You need to go up in voltage, not down.

        Try it on 240v. (check your 5v supply can handle that, or power it separately)

        • dansity@lemmy.dbzer0.comOP
          link
          fedilink
          English
          arrow-up
          1
          ·
          1 year ago

          I have 230V or 400V three phase. I live in the EU. So this cannot be solved without replacing the winding on the transformer I guess.

          • BigDanishGuy@sh.itjust.works
            link
            fedilink
            English
            arrow-up
            1
            ·
            1 year ago

            If it’s just a matter of getting a larger voltage, then you already got 400V. No need for new windings, unless the insulation on the primary can’t handle 400V.

          • SomeoneSomewhere@lemmy.nz
            link
            fedilink
            English
            arrow-up
            1
            ·
            11 months ago

            If you have a 230V supply and a 230V transformer, you are fine. I believe they thought you were using a 120V supply on a 230V transformer.

            Raising the input voltage will probably not get you what you want.